Catálogo
6 foto
4 Avaliações
3.5
qm******dt - 0
qm******dt
04 Oct 2024
H
hk*is
03 Oct 2024
da******ng - 2
da******ng
10 Oct 2024
T
th**********na
04 Oct 2024
Características
Origin
Mainland China
Package
Yes
Channels
2 (2.0)
Brand Name
GHXAMP
Certification
none
Maximum Power Per Channel
NO POWER
Descrição

90-265V All can use

FEATURES
This unit is radio-interference suppressed. This appliance meets the requirements of the current European and national guidelines. Conformity has been established and the relevant statements and documents have been deposited by the manufacturer.

SPECIFICATIONS:

Power Supply:AC 230V. 50Hz .
Frequency response:10-20000Hz .
Controllable Frequencies:
25/40/63/100/160/250/400/630Hz;
1/1.6/2.5/4/6.3/10/16 KHz .
Control Range:Switchable to +/- 6dB or +/-12dB .
Low Cut Filter:20Hz/-12dB .
THD + noise:<0.1%@ 1kHz,0dB .
S/N Ratio (IHF-A):>66dB @1kHz.
lnputs:775mV @ 50K ohms .
Output:775mV @ 600 ohms .

2*15-band stereo equalizer;
Balanced or unbalanced connections;
Level switch: +6 dB/+12 dB;
Equalizer bypass switch;
Subsonic filter switch;
Standard 19"-1Unit rack format.


BEFORE USE :
Before you start using this unit, please check if there's no transportation damage.Should there be any, do not use the device and consult your dealer first.

lmportant: This device left our factory in perfect condition and well packaged. lt is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual.Any damage caused by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. lf you sell the fixture, be sure to add this user manual.

To protect the environment, please try to recycle the packing material as much as possible.

Check the contents:
Check that the carton contains the following items:
User manual;
The EQ215 or BEQ15 equalizer).


SAFETY INSTRUCTIONS:

CAUTION: To reduce the risk of electric shock,do notremove the top cover. No user-serviceable parts inside.Refer servicing to qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage"within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance.

This symbol means: indoor use onlyThis symbol means: Read instructions;
This symbol means: Safety Class ll appliance.


.To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
. To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages.

. This unit is for indoor use only.
. Don't place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be placed on this appliance. Electric shock or malfunction may result.lf a foreign object enters the unit, immediately disconnect the mains power.
. No naked flame sources, such as lighted candles, should be placed on the appliance.
. Don't cover any ventilation openings as this may result in overheating.
. Prevent use in dusty environments and clean the unit regularly.
. Keep the unit away from children.
. Inexperienced persons should not operate this device.
. Maximum save ambient temperature is 40°℃. Don't use this unit at higher ambient temperatures.
. Minimum distances around the apparatus for sufficient ventilation is 5cm.
. Always unplug the unit when it is not used for a longer time or before you start servicing.
. The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country.
. Check that the available voltage is not higher than the one stated on the rear panel of the unit.
. The socket inlet shall remain operable for disconnection from the mains.
. The power cord should always be in perfect condition. Switch the unit immediately off when the power cord is squashed or damaged.It must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
. Never let the power-cord come into contact with other cables!
. When the power switch is in OFF position, this unit is not completely disconnected from the mains!
. In order to prevent electric shock,do not open the cover. Apart from the mains fuse there are no user serviceable parts inside.
. Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same type and electrical specifications!
. in the event of serious operating problems, stop using the appliance and contact your dealer immediately.
. Please use the original packing when the device is to be transported.
. Due to safety reasons it is prohibited to make unauthorized modifications to the unit.


INSTALLATION GUIDELINES:
. Install the unit in a well-ventilated location where it will not be exposed to high temperatures or humidity.

. Placing and using the unit for long periods near heat-generating sources such as amplifiers, spotlights, etc, will affect its performance and may even damage the unit.

· The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes on the front panel.Be sure to use screws of the appropriate size, (screws not provided)Take care to minimize shocks and vibrations during transport.

. When installed in a booth or flight case,please make sure to have good ventilation to improve heat evacuation of the unit.

. To avoid condensation to be formed inside,allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance.


CLEANING THE APPLIANCE :
Clean by wiping with a polished cloth slightly dipped with water. Avoid getting water inside the unit. Do not use volatile liquids such as benzene or thinner which will damage the unit.

Package :1pc.

Title 1, Dual 15-band Equalizer Stereo Professional Stag...
Title 2, Dual 15-band Equalizer Stereo Professional Stag...Title 3, Dual 15-band Equalizer Stereo Professional Stag...
Title 4, Dual 15-band Equalizer Stereo Professional Stag...Title 5, Dual 15-band Equalizer Stereo Professional Stag...Title 6, Dual 15-band Equalizer Stereo Professional Stag...Title 7, Dual 15-band Equalizer Stereo Professional Stag...Title 8, Dual 15-band Equalizer Stereo Professional Stag...Title 9, Dual 15-band Equalizer Stereo Professional Stag...Title 10, Dual 15-band Equalizer Stereo Professional Stag...Title 11, Dual 15-band Equalizer Stereo Professional Stag...Title 12, Dual 15-band Equalizer Stereo Professional Stag...Title 13, Dual 15-band Equalizer Stereo Professional Stag...Title 14, Dual 15-band Equalizer Stereo Professional Stag...Title 15, Dual 15-band Equalizer Stereo Professional Stag...Title 16, Dual 15-band Equalizer Stereo Professional Stag...Title 17, Dual 15-band Equalizer Stereo Professional Stag...Title 18, Dual 15-band Equalizer Stereo Professional Stag...Title 19, Dual 15-band Equalizer Stereo Professional Stag...Title 20, Dual 15-band Equalizer Stereo Professional Stag...Title 21, Dual 15-band Equalizer Stereo Professional Stag...

Package
1pcs


Ver mais
91.26$
134.2$
3.5
4 reviews 11 verkopen

Dual 15-band Equalizer Stereo Professional Stage Home Audio Tone Preamplifier Speaker EQ Equalizer Tuner Equipment 90V-2

Entrega editar Brazil
1
Em estoque: 9980
Peça agora
Adicionar ao carrinho
Publicados: 18.04.2024 17:48 Em estoque: 9980 1.24KVisualizações

Anúncios da mesma categoria